設計ガイドライン

Ultem 9085

General guidelines

技術仕様

Maximum part dimensions

914 x 610 x 914 mm

406 x 355 x 406 mm (online orders)

Standard accuracy

 ±0.15% (with a lower limit on ±0.2 mm)

Layer thickness

0.25 – 0.33 mm

Minimum wall thickness

1.2 mm

Minimum detail size

0.3 mm

Interlocking or moving parts

No

Internal channels

No

Surface structure

Rough surface with visible layers